DC30 Series - Moter Protection Controller
Motor Protection Controller DC30M

1.     Summarize

DC30M is suitable for 3-phase AC asynchronous motor monitoring, protection and control. Featured with compact modular structure, small volume and easy installation, it can be applied to all kinds of draw-out, fixed or mixed cabinet, such as MNS、GCS、GCK、GGD…

2.     Typical Product Pictures

3.     Models and Meaning of Products

4.     Factory Default

Mutual Inductor

Rated Current (A)

Mutual Inductor

Primary Turns (T)

Setting Current (Is)

Rang (A)

Power of Motor

(kW)

6.3

1

1.6~6.3

0.37~3

30

1

6.3~30

3~15

100

1

30~100

15~55

250

1

63~250

30~132

800

1

250~800

132~440

5.     Main Functions

Model

Product function

Function configuration

Default

Optional

Protection function

Start overtime

√

-

Over load

√

-

Over current jam

√

-

Phase loss

√

-

Current unbalance

√

-

Earthing

√

-

Short circuit

√

-

Leakage current (With external CT)

-

√

Under load

-

√

Temperature (PTC / NTC)

-

√

Over voltage (control loop voltage)

-

√

Voltage function

under voltage (control loop voltage)

-

Frequency

-

Under power factor

-

Phase protection

-

Running mode

Protection

√

Programm-able

-

Direct start directly

-

Reversible bidirectional start

-

Star-delta start with two relays

-

Star-delta start with three relays, open loop

-

Star-delta start with three relays, closed loop

-

Auto-transformer transformer start with two relays

-

Auto-transformer transformer start with three relays, open loop

-

Auto-transformer transformer start with three relays, closed loop

-

Communication

RS485 Interface, Modbus-RTU protocol

-

√

Opto-couplers signal input

√

-

Relay output

Control relay J1, programmable

√

-

Signal relay J2, programmable

√

-

Analog output

1-way DC4-20mA, programmable

-

√

LED indicate

Run, Bus, Fault

√

Measurement display

Thermal resistance

√

Voltage function

Three-phase voltage

Frequency

-

Power factor

-

Active/Reactive power

-

Three-phase current

√

-

Ground/Leakage current

√

-

Three-phase current unbalance ratio

√

-

Thermal capacity

√

-

Protection setting

All protection parameters enquiry and adjust

√

-

System setting

System time setting

√

-

Fault record

More than 8 time fault signals, resolution 1s

-

√

Statistical information

Real-time reading total running time, total stop time, operation times, stop times

-

√

Remark:

1)     “√” means the model has the function.

2)     “ – “ means the model doesn’t have such function.

3)     The number means channel, for example: 2 means the model has the function with 2 channels.

6.     Technical Specifications

Description

Parameters

Power supply

AC/DC 85~265V,220V, AC380V (�15%)

Power consumption

15W / 15VA

Rated voltage of motor

AC0~1000V (50Hz)

Rated current of motor

2A (0.5A~2A)

Internal current mutual inductor detection module.

5A (1A ~ 5A)

6.3A (1.6 ~ 6.3A)

30A (6.3A ~ 30A)

100A (30A ~ 100A)

250 A (100A ~ 250A)

External current mutual inductor detection module.

800 A (250A ~ 800A)

800 A (300A ~ 800A)

Contactor capacity

Control Relay

AC250V / 5A

Signal Relay

DC30V / 5A

On-off input (External active node)

Opto-couplers isolation, AC/DC 220V

Work environment

Temperature

-10℃~55℃

Relative humidity

≤93%RH

Altitude

Non-corrosive gas forum, Altitude ≤2500m

Storage environment

Temperature

-20℃~75℃

Relative humidity

≤93%RH

7.     Outline Dimension

8.     Typical Functions Wiring Diagram

 Note: the above diagram is only for reference, the actual parameters in the factory shall prevail.

9.     Ordering Example

l   Model: DC30M-010FT

l   Input Signal: AC220V, 50Hz

l   Rated Current Of Motor: 10A

l   Communication: RS485, Modbus-RTU

l   Quantity: 100pcs

l   Additional Function: DC4-20mA analog output

l   Installation: split structure, 3m away

l   Other: other factory pre-sets (if no indication when ordering, ex-factory products will be delivered in accordance with the default setting).